X

Archived Roof Coating Systems

Archived roof coatings are classic NEOGARD coating systems with long-standing use in the construction coatings industry. Systems include LEED, BioPreferred and California's AQMD certified products. Click the 2015 roofing products button to return to our standard roofing products.

 

Current Roofing Systems

 

Archived Fluid-Applied Roof Coating Systems

  • Elasta-Gard BUR/MB - Urethane system (7419/7441 series) for use over smooth surfaced BUR/MB or granulated cap sheet.
  • Elasta-Gard BUR/MB II - Urethane system (7419/70611 series) for use over smooth surfaced BUR/MB or granulated cap sheet.
  • Elasta-Gard BUR/MB III - Urethane system (70620/70630 series) for use over smooth surfaced BUR/MB or granulated cap sheet.
  • Elasta-Gard C - Urethane system (7419/7441 series) for use over concrete surfaces.
  • Elasta-Gard C II - Urethane system (7419/70611 series) for use over concrete surfaces.
  • Elasta-Gard C III - Urethane system (70620/70630 series) for use over concrete surfaces.
  • Elasta-Gard M - Urethane system (7441 series) for use over metal surfaces.
  • Elasta-Gard M II - Urethane system (70611 series) for use over metal surfaces.
  • Elasta-Gard M III - Urethane system (70630 series) for use over metal surfaces.
  • Elasta-Gard SP - Urethane system (7419/7441 series) for use over single ply membranes such as TPO, PVC, EPDM, etc.
  • Elasta-Gard SP II - Urethane system (7419/70611 series) for use over single ply membranes such as TPO, PVC, EPDM, etc.
  • Elasta-Gard SP III - Urethane system (70620/70630 series) for use over single ply membranes such as TPO, PVC, EPDM, etc.

Archived Sprayed Polyurethane Foam Roof Coating Systems

  • Permathane FR - Urethane system (7419/7441series) for use over 2.7 - 3.2 pound density polyurethane roofing foam.
  • Permathane II FR - Urethane system (70620/70611 series) for use over 2.7 - 3.2 pound density polyurethane roofing foam.
  • Permathane III - Urethane system (70620/70630 series) for use over 2.7- 3.2 pound density polyurethane roofing foam.

Fluid-Applied Roof Coating Systems

  • Elasta-Gard BUR/MB - Urethane system for use over smooth surfaced BUR/MB or granulated cap sheet.
  • Elasta-Gard BUR/MB II - Urethane system for use over smooth surfaced BUR/MB or granulated cap sheet.
  • Elasta-Gard BUR/MB III - Urethane system for use over smooth surfaced BUR/MB or granulated cap sheet.
  • Elasta-Gard C - Urethane system for use over concrete surfaces.
  • Elasta-Gard C II - Urethane system for use over concrete surfaces.
  • Elasta-Gard C III - Urethane system for use over concrete surfaces.
  • Elasta-Gard M - Urethane system for use over metal surfaces.
  • Elasta-Gard M II - Urethane system for use over metal surfaces.
  • Elasta-Gard M III - Urethane system for use over metal surfaces.
  • Elasta-Gard SP - Urethane system for use over single ply membranes such as TPO, PVC, EPDM, etc.
  • Elasta-Gard SP II - Urethane system for use over single ply membranes such as TPO, PVC, EPDM, etc.
  • Elasta-Gard SP III - Urethane system for use over single ply membranes such as TPO, PVC, EPDM, etc.

Sprayed Polyurethane Foam Roof Coating Systems

  • Permathane FR - Urethane system (7419/7441 series) for use over 2.7 - 3.2 pound density polyurethane roofing foam.
  • Permathane II FR - Urethane system 70620/70611 series) for use over 2.7 - 3.2 pound density polyurethane roofing foam.
  • Permathane III - Urethane system (70620/70630 series) for use over 2.7- 3.2 pound density polyurethane roofing foam.

Liquid Additives

Primers

Roofing

  • 70611 Series - 1K Aromatic Urethane Topcoat
  • 70611-CA Series - 1K Aromatic Urethane Topcoat
  • 70613-BIO - 1K Aromatic Biobased Urethane Topcoat
  • 70620 - 1K Aromatic Urethane Base Coat
  • 70620-CA - 1K Aromatic Urethane Base Coat
  • 70620-BIO - 1K Aromatic Biobased Urethane Base Coat
  • 70630 - 1K Aromatic Urethane Topcoat
  • 7251 Series - 1K High Solids Acrylic Coating
  • 7261 Series - 1K High Solids Quick Set Acrylic Coating
  • 7419 - Aromatic Urethane Base Coat (Requires 7932 Additive)
  • 7419-CA - Aromatic Urethane Base Coat (Requires 7932 Additive)
  • 7419-HB - 1K High Build Aromatic Urethane Base Coat
  • 7441 Series - Aromatic Urethane Topcoat (Requires 7923 Additive)
  • 7490 - 1K Aliphatic Urethane Topcoat
  • 7810 - Butyl Urethane Base Coat (Requires 7932 Additive)
  • 7860-LO - 1K Low Odor RTV Silicone Coating

Acrylic Urethane Catalyzed Coatings

Aggregates

Miscellaneous Products

  • 20653 (Xylene Thinner) - For Thinning & Cleaning Equipment
  • 3781 (Block Filler) - Acrylic Latex Block Filler
  • 7032-04 - Knife Grade Acrylic Elastomeric Patching Compound
  • 7055 - Odorless Reducer for Low Odor/Odor Free Urethanes
  • 70991 - 1K Non-Sag Polyurethane Sealant
  • 70995 - 2K Non-Sag Polyurethane Sealant
  • 8500 - Water Soluble Concentrate BioDegradable Cleaner
  • 86218 - Eternabond WebSeal Flashing Tape
  • 86220 - Tietex Stichbonded Polyester Roofing Fabric T272

 Summary Application Table for Smartphones

  • Roofing Summary Application Table - Quick-reference guide with application rates for NEOGARD Fluid-Applied Roof Coating Systems. This PDF is designed to be readable on smartphone screens.

Application Manuals

Troubleshooting Guide

Maintenance Manual

The following manuals provide suggested procedures for physical inspections, ice and snow removal, cleaning and emergency repair.

Bulletins/Quick Notes

  • Topcoat SRI Values - Total Emittance and Hemispherical Spectral Reflectance test results of NEOGARD Topcoats.

Selection Guides

DFT Chart

  • DFT Chart  - Theoretical dry film thickness for roof coating products.

Curing Charts

The following cure charts provide information such as pot life, sag resistance, gel time, recoat and cure times when using accelerators.

7414 • 7419 • 7419-HB

70410 • 7430 Series

FC7510/FC7961 • FC7540/FC7964

70611 Series

Chemical Resistance Charts

70611 Series

70630

70704/70705

70708/70709

70714/70715

70714/70715-09

70724/70715

70734/70735

70805/7952

70815/70816

70860/70865

70866/70816

7430 Series

7490

ACRYLITHANE™ C

ACRYLITHANE™ HS2

ACRYLITHANE™ HS3

ACRYLITHANE™ HS4

 

 

Color Cards

The Leadership in Energy and Environmental Design (LEED) Green Building Rating System™ is the nationally accepted benchmark for design, construction, and operation of high performance green buildings. LEED provides building owners and operators the tools they need to have an immediate and measurable impact on building performance. LEED promotes a whole-building approach to sustainability by recognizing performance in seven key areas of human and environmental health: Sustainable Sites (SS), Water Efficiency (WE), Energy and Atmosphere (EA), Materials and Resources (MR), Indoor Environmental Quality (IEQ), Innovation in Design (ID), and Regional Priority (RP). 

 

Visit the USGBC for more information on LEED

 

Available LEED Credit Letters:

Roofing (SSc7.2, MRc5, MRc6) - June 1, 2014